S1200 Hospital Medical Equipment Portable Surgical ICU Respirator Ventilator Machine
Intended Usage S1200 medical ventilator is applicable for all kinds of medical, respiratory support for resuscitation of heart, lung, and brain; acute respiratory insufficiency or oxygenation dysfuction caused by different reasons, respirtory support during or after the surgery, other patients who need respiratory therapy. Suit for children and adult.
Indications Respiratory support of resuscitation of heart, lung and brain;
acute respiratory insufficiency or oxygenation dysfuction caused by different reasons;
respirtory support during or after the surgery;
other patients who need respiratory therapy
Contraindications Ventilator don't have absolute contraindications, but the operator should pay attention to relative contraindication such as severe lung disease. These kind patient should pay attention.
Main features: *Electric control and pneumatical driven
*Applicable to both adults and children
*15'' TFT Touch LCD display screen
*Multiple working mode and ventilation modes such as IPPV,A/C,PCV,SIMV,SPONT/CPAP,PSV ,SIGH,MAUN
*With alarming functions
*With realtime compensation function
*With air and oxygen mixer of high accuracy,stable and reliable.
*With built-in spare power source,when outside power source goes off, back up power source starts to work
*Compatible with air compressor
* With nebulizer function
* With inspiratory hold, expiratory hold and waveform freeze function
* With manual ventilation function
Work condition: Gas source:O2, compressed air
Rated working pressure:280kpa~600kpa
Power source: Voltage ~220V±22V
Frequency:50HZ±1HZ
Input power: 900VA(Equip with air compressor), 250VA(Without air compressor)
Main parameters Adjusting range of parameters: Frequency:1 bpm ~ 100 bpm SIMV mode:1 bpm~ 40 bpm
Other modes: Adult4 bpm~ 40 bpm Children:20bpm~ 100 bpm Tinsp(inspiratory time):0s~ 12s(Except for SIMV mode Respiratory ratio::4:1~1:8) VT(Tidal volume) range: 0 mL ~ 2000 mL Adult:250mL ~ 2000 mL Children: 0 mL ~ 300 mL MV Adult Vt ≥ 18L/min, Children Vt ≥ 10L/min PEEP: 0 cmH2O ~ 40 cmH2O CPAP: 0 cmH2O ~ 20 cmH2O Continuous air flow : Adult: 0 L/min ~ 60 L/min Children:2 L/min ~ 30 L/min PTr(Pressure trigger):- 20cmH2O ~ 20 cmH2O FTr:(Flow trigger)0.5 L/min ~ 30 L/min Pc(Pressure control):5cmH2O ~ 80 cmH2O Ps(Pressure support): 0 cmH2O ~ 80 cmH2O Adjusting range of O2 concentration: 21 %~100 % Holding time(Inhalation platform /TIP): 0 ~ 6s(≤50 % inspiratory time) SIGH adjusting range:1/100 ~ 5/100 Suffocation ventilation: OFF,5 s ~ 60 s Max inspiratory flow ≥ 60 L/min Pressure limit range:20cmH2O ~ 100 cmH2O Max safety pressure<12.5Kpa Manual ventilation flow speed: ≥25L/min Nebulizer gas: Maximum output pressure ≤0.2Mpa Maximum output flowspeed ≥8L/min Pressure rise time: 0.1-2.0S
Monitoring parameters: Frequency:0 /min ~ 100 /min VT(Tidal volume):0 mL ~ 2500 mL MV(Tidal volume/min):0 L/min ~ 99 L/min Tube pressure:0 cmH2O ~ 100 cmH2O Patient Lung dynamic compliance monitoring : 1ml/cmH2O ~ 1000ml/cmH2O Concentration of inhaled oxygen:15 % ~ 100 % EtCO2 Concentration: 0mmHg ~ 152 mmHg (0-20%) Inspiratory Time: 0-12S Graphical display Tube pressure-time wave form
Air flow-time wave form
Pressure volume loop
Volum-time wave form
EtCo2-time wave form
Alarming and protection function: Alarm when AC power off
Alarm when spare power voltage getting low
Alarm when there's no tidal volume
Alarm when ventilation volume too high or too low
Alarm when tube pressure too high or too low
Pressure limits
Continuous pressure alarm
Alarm when concentration of Oxygen too high or too low
Alarm when suffocation occurs
Pressure safety relief valve<125cmH2O
System fault alarm
Low input gas pressure alarm
Low oxygen supply pressure alarm