Customization: | Available |
---|---|
Color: | Blue |
Folded: | Folded |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1. Used for isolation and transportation of severe respiratory infections, preventing pathogen spread and reducing infection rate of medical staff.
2. The cabin is made of high-quality, durable, pollution-free and high-strength transparent TPU material, with waterproof and sealed zippers.
3. Arch supported by the support rod, 2 oxygen inlet, for patients infusion and oxygen delivery; There are 10 operating ports and gloves for patient care and maintenance.
4. The battery can be used continuously for at least 4 hours on a full charge.
5. It can be used together with stretcher to facilitate the movement of patients.
The negative pressure of not less than 15Pa is rapidly established within 6.2min.
7. The noise in cabin is not more than 65dB (A).
8. The filtration efficiency of 0.3μm aerosol particles is not less than 99.99%.
9. Air change in cabin is not less than 50L/min.
10. Sound and light alarm will be made in isolation cabin when the internal negative pressure is insufficient or the electric quantity is too low.
11. When unloaded, the total weight of the cabin shall not be more than 20Kg.
12. Optional stretcher can bear up to 150Kg.
13. It is equipped with 8 long aluminum rods and 4 short aluminum rods to support the cabin, prevent the cabin from shaking and collapsing, and keep the negative pressure stable.
14. The inner plate of the cabin isolation room is equipped with straps for securing the patient and an outer strap for securing the isolation room to a stretcher or bed.
15. The cabin is equipped with three high efficiency filters (canisters) to ensure safety
16. The battery lasts about 10 hours on a full charge.
17. When the internal negative pressure is insufficient or the electric quantity is too low, sound and light alarm should be conducted in the isolation room.
18. The isolation chamber is a fully foldable device that requires minimal storage space and can be used within minutes.
Model | EA-13A |
Unfolded Size (L*W*H) | 1900*680*500mm |
HEPA Filter | 3pcs, 99.99% efficiency for 0.3μm particles |
Ventilation | ≥ 50L/min |
Chamber Noise | ≤65dB(A) |
Alarm | Audio and visual alarm for internal pressure insufficient and low power |
Negative Pressure | ≥15 Pa in two minutes after power on |
Standard Accessory | The main chamber, 3pcs disposable HEPA filter, Negative generation system, 5 pairs PE gloves, Battery and charger, 8 long aluminum rods, 4 short aluminum rods,8 knurled bolts |
Consumables | HEPA filter (3pcs/set), PE gloves |
Disinfection | Disinfect the chamber with formalin and neutralize with ammonium hydrogen carbonate |
Optional | Folding stretcher; Stretcher trolley |
Load-Bearing | Up to 150kg |
Power Supply | DC12V power adapter. Battery charging for 12 hours and continuously using for 10 hours |
Package Size (L*W*H) | 870*680*740mm |