• F8-S Hospital Medical Emergency Portable Patient Care ECG Multi-Parameter Patient Monitor

F8-S Hospital Medical Emergency Portable Patient Care ECG Multi-Parameter Patient Monitor

Classification: Physiological Functions of Diagnosis and Monitoring Equipment
Type: Patient Monitor
Certification: CE, FDA
Group: Adult, Pediatric and Neonatal Patient
Power Requirements: AC 90-300V, 50/60Hz, 60W
Size: 375mm(W)*330mm(H)*180mm(D)
Customization:
Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
F8-s
Certificates
SGS, ISO
Display Mode
Standard, Large Font, Trend Table, Full Lead ECG,
OEM
Supply
Battery
Rechargeable Battery, 2.2 Ah 12V
Transport Package
Export Package
Specification
SGS, ISO
Trademark
WANROOEMED
Origin
China
HS Code
94029000
Production Capacity
500 Sets/Month

Product Description

F8-S Hospital Medical Emergency Portable Patient Care ECG Multi-parameter Patient Monitor 
F8-S Hospital Medical Emergency Portable Patient Care ECG Multi-Parameter Patient Monitor


Features:
1. 12.1'color TFT LCD screen
2. Acoustic and visual alarm
3. Display mode: Standard, Large Font, NIBP Trend, Trend Table, Full lead ECG, Oxy CRG
4. Drug calculation and titration table
5. Real time ST segment analysis, pacemaker detection and Arrhythmia analysis
6. Suitable for monitoring adult, pediatric and neonatal patient
7. Supporting storage of 240 hours patient data, 1024 NIBP records and 1024 alarm event
8.
Isolated against defibrillation effect

Configuration:
3-lead or 5-lead ECG/HR, RESP, Dual TEMP, SpO2/PR, NIBP
F8-S Hospital Medical Emergency Portable Patient Care ECG Multi-Parameter Patient Monitor

Optional configuration:
Touch screen, Printer, Trolley, Wall-mount

Dimension and weight Dimension 375mm(W)*330mm(H)*180mm(D)
Weight standard configuration: 4.4 kg
Operation environment Power requirements AC 90-300V, 50/60HZ, 60W
Power 90VA
Temperature 0-40ºC
Humidity 0-93% non-condensing
Safety Meet the requirements of IEC60601 series
Patient range Adult, neonate and pediatric patients
Performance Specification
Display                            12.1 inch (800 x 600 pixel) color TFT LCD rolling and refreshing waveform display
Display mode Standard, large font, trend table, full lead ECG, Oxy CRG,NIBP trend
Interface
 
Parameter cable interface
AC power input socket
Battery Rechargeable battery, 2.2 Ah 12V
Alarm indicator Visual on-display and integrated alarm light
Audible alarm and personated voice reminding alarm
Data storage
 
240 hours monitoring data
1024 NIBP records storage 
1024 alarm event    
Printer
 
 
Built-in 50mm thermal printer (option), 
2 traces, print speed 25mm/s & 50mm/s   
print width:50mm
ECG
Leads type 3(option)/5-lead : I, II, III, aVR, aVL, aVF, V
Sweep speed 12.5mm/s, 25mm/s 50mm/s
Gain selection ×0.25, ×0.5, ×1, ×2
ECG waveform 1 channels
Operation mode Diagnostic, monitor, surgery
Heart rate range 0 -300bpm
Accuracy 1bpm or ±1% whichever is great
Alarm range Audible and visual alarm, adjustable
ST/ arrhythmia Real time S-T segment detection, pace detection and arrhythmia analysis
Protection Against electrosurgical interference and defibrillation
Respiration (RESP)
Method Thoracic impedance
Operation mode Auto
Measurement range Adult: 0-120BrPM; neonatal /pediatric: 0-150BrPM
Apnea alarm Yes
Alarm Yes, audible and visual alarm ,alarm events recallable
NIBP
Method Automatic oscillometric
Operation mode Manual/Automatic/STAT
 
Auto measure time Adjustable
Measurement unit mmHg / kPa  selectable
Test interval 1-480 minutes
Measurement range
 
 
Adult: 0-300 mmHg ;    
Child: 0-240 mmHg ;     
Infant: 0-150 mmHg
Over-pressure protection Double safety protection
Accuracy of blood pressure      measurement The mean error shall be less than±5mmHg
the standard deviation shall be less than 8mmHG
Resolution 1 mmHg
SPO2
Measurement range 0%-100%
Resolution 1%
Accuracy ±2% (70-100%, adult/pediatric, non-motion )
±3% (70-100%, neonate, non-motion )
±3% (70-100%, adult/pediatric/neonate, motion )
0-69% unspecified
Alarm range 1-100%
Pulse rate                          Pulse range: 20-300bpm
Accuracy: ±3bpm(non-motion)
±5bpm(motion )
Temperature (TEMP)
TEMP range 0-50ºC
Resolution 0.1 ºC
Accuracy   ±0.1ºC  (excluding the sensor)  
  Channel   Single channel.  


Company Information:
F8-S Hospital Medical Emergency Portable Patient Care ECG Multi-Parameter Patient Monitor
F8-S Hospital Medical Emergency Portable Patient Care ECG Multi-Parameter Patient Monitor
 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory
Management System Certification
ISO 9001, ISO 13485
Import & Export Mode
Have Own Export License