Hb-Yp910 Hospital Neonatal Care Infant Warmer Incubator
Brief Introduction: Two control modes: Air mode and baby mode controlled by micro-computer
Humidity concentration display system
Humidity control system(for HB-YP920)
Set temperature, air temperature, baby temperature, humidity concentration are displayed separately;
>37°C temperature set function;
Failure alarm indication;
Embedded integrated sensor box
Integrated water reservoir in the shape of drawer(for HB-YP920);
Double wall hood, automatic air circulation device;
Inclination of bassinet is adjustable;
RS-232 connector;
Oxygen input interface;
DC motor.
Standard Configuration: HB-YP910: The hood, the base, the mobile cabinet, the controller, I.V pole, tray; HB-YP920: Based on HB-YP910, with Humidity control system.
Optional Configuration: Fixed neonate bilirubin phototherapy equipment model:HB XHZ-90 (with blue fluorescent lamps);
Fixed neonate bilirubin phototherapy equipment model: HBXHZ-90L (with LED blue lights);
Vertical height adjustment stand (VHA stand), Weighing system , SPO2 and Disposable skin temperature sensor.
Specification: Power requirement: AC220V-230V/50Hz or AC110-120V/50-60Hz, 850VA ( HB-YP910 )
AC220V-230V/50Hz or AC110-120V/50-60Hz, 1000VA (HB-920)
Mode of control: Air mode and baby mode controlled by micro-computer
Air temperature control range: 25°C -37°C (override mode 37-39°C )
Baby temperature control range: 34-37°C (override mode 37-38°C )
Accuracy of skin temperature sensor: ±0.2°C
The temperature difference between incubator temperature and average incubator temperature (under steady temperature condition)≤0.5°C
Temperature uniformity≤0.8°C (mattress is on the horizontal position)
Inclination of the bassinet: ±12° la Noise inside hood: 45dB(A)
Failure alarm: over temperature alarm, deviation alarm, sensor failure alarm, fan motor alarm, power failure alarm, sensor box position alarm and system alarm. (HB-YP920 has low water alarm and tank position alarm)
Humidity display range: 0%RH-99%RH
Humidity control range: 0%RH-90%RH (for HB-YP920)
Accuracy of humidity display: ±5%RH(environment temperature is 25°C , environment humidity is 45%RH±5%RH)
Environmental temperature: Operating range: 20 °C -30°C (Set temperature should be higher 3°C than the environment temperature)
Ambient air movement rate: <0.3m/s
Product Packaging: Package: each unit is packed into two cartons
Dimension (Main body): 1085mm x 640mm x 910mm
(Cabinet): 1125mm x 665mm x 725mm
Gross Weight (Main body):63Kg (for HB-910)
66Kg(for HB-920)