• F5 A8 12.1 Inch Medical Portable Clinic Diagnostic Multi Parameter Patient Monitor
  • F5 A8 12.1 Inch Medical Portable Clinic Diagnostic Multi Parameter Patient Monitor
  • F5 A8 12.1 Inch Medical Portable Clinic Diagnostic Multi Parameter Patient Monitor

F5 A8 12.1 Inch Medical Portable Clinic Diagnostic Multi Parameter Patient Monitor

Classification: Physiological Functions of Diagnosis and Monitoring Equipment
Type: Patient Monitor
Certification: CE, ISO13485
Group: Adult, Pediatric and Neonatal Patient
Display Mode: Standard, Big Font, Trend Table, Full-Lead ECG, Ox
Dimension: 340mm(W)*280mm(H)*130mm(D)
Customization:
Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
F5 A8
12.1 Inches
Yes
Patient Range
Adult, Neonate and Pediatric Patients
Extended Advance Function
2IBP, Depth of Anesthesia, Etco2 , Nellcor SpO2
Battery
1 Internal Large Capacity Rechargeable Lithium Bat
Printer
Built-in 50mm Thermal Printer (Option)
Power Requirements
AC 100-240V, 50/60Hz, 60W
Factory Location
1.5 Hours From Shanghai
SpO2
Optional
Transport Package
Export Carton Package
Specification
CE, ISO
Trademark
WANROOEMED
Origin
China
HS Code
94029000
Production Capacity
1000PCS/Month

Product Description

F5 A8 12.1 Inch Medical Portable Clinic Diagnostic Multi Parameter Patient Monitor
F5 A8 12.1 Inch Medical Portable Clinic Diagnostic Multi Parameter Patient Monitor

Features

¨          12.1' color TFT LED screen supports display max. 8 waveforms 
¨          Visual On-display and integrated alarm light 
¨          Display mode: standard, large font, trend table, OxyCRG, full leads ECG
¨          Arrhythmia analysis and real-time S-T segment analysis and pacemaker detection
¨          Drug calculation, titration table
¨          Suitable for monitoring adult, pediatric and neonatal patient.
¨          Extended advance function: 2IBP, Depth of Anesthesia, EtCO2 , Nellcor SpO2
Standard Configuration:
¨          Anti-glare screen, Large capacity rechargeable battery,  3/5-Lead ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature
Optional Configuration:
¨          Dual IBP, Nellcor SpO2, MASIMO SpO2, Depth of Anesthesia Monitoring Module, EtCO2 (Main-stream/Side-stream)
¨          Thermal printer (50 mm)
¨          Pediatric / neonatal accessories: reusable NIBP cuff & SpO2 probe; disposable NIBP cuff & SpO2 probe
¨          Central Monitoring System
¨          Touch Screen
¨          Trolley/Wall Mount
Physical Specifications
Dimension and weight Dimension 340mm(W)*280mm(H)*130mm(D)
Weight Standard configuration: 4 kg
Operation environment Power requirements AC 100-240V, 50/60HZ, 60W
Power 90VA
Temperature 0-40ºC
Humidity 0-93% non-condensing
Safety Meet the requirements of IEC60601 series
Patient range Adult, neonate and pediatric patients
Performance Specification
Display                          12.1' (800 x 600 pixel) color TFT LED screen
Display mode Standard, big font, trend table, full-lead ECG, Oxy CRG.
Interface
 
Parameter cable interface
AC power input socket
Network interface
Battery 1 internal large capacity rechargeable lithium battery
Alarm indicator Visual on-display and integrated alarm light
Audible alarm
Data storage
 
108 hour trend graph
168 hour trend table
2 hour trend wave 
1024 alarm events
Printer
 

 
Built-in 50mm thermal printer (option), 
3 traces, print speed 12.5mm/s & 25mm/s & 50mm/s   
Print width: 50mm
Net working Support connection to central monitoring station through LAN (TCP/IP) or wireless connection
ECG
Leads type 3/5 lead : I, II, III, aVR, aVL, aVF, V
Sweep speed 12.5mm/s, 25mm/s,50mm/s
Gain selection ×0.25, ×0.5, ×1, ×2, Auto
ECG waveform 2 channels
Operation mode Diagnostic, monitor, surgery
Heart rate range 0 - 350bpm
Accuracy 1bpm or ±1% whichever is great
Alarm range Audible and visual alarm, adjustable
ST/ arrhythmia Real time S-T segment detection, pace detection and arrhythmia analysis
Protection Against electrosurgical interference and defibrillation
Respiration (RESP)
Method Thoracic impedance
Operation mode Auto
Measurement range Adult: 0-120BrPM; neonatal /pediatric: 0-150BrPM
Apnea alarm Yes
Alarm Yes, audible and visual alarm ,alarm events recallable
NIBP
Method Automatic oscillometric
Operation mode Manual / Automatic / STAT
Auto measure time Adjustable
Measurement unit mmHg / kPa  selectable
Test interval 1-480 minutes
Measurement range
 

 
Adult: 0-300 mmHg ;    
Child: 0-240 mmHg ;     
Infant: 0-150 mmHg
Over-pressure protection Double safety protection
Accuracy of blood pressure      measurement The mean error shall be less than ± 5mmHg
The standard deviation shall be less than 8mmHG
Resolution 1 mmHg
SPO2
Measurement range 0%-100%
Resolution 1%
Accuracy ±2% (70-100%, adult/pediatric, non-motion )
±3% (70-100%, neonate, non-motion )
±3% (70-100%, adult/pediatric/neonate, motion )
0-69% unspecified
Alarm range 1-100%
Pulse rate                        Pulse range: 0-350bpm
Accuracy: ±3bpm(non-motion)
±5bpm(motion )
Temperature (TEMP)
TEMP range 0-50ºC
Resolution 0.1 ºC
Accuracy ±0.1ºC  (excluding the sensor)
Channel Dual-channel. provide T1;T2; T
IBP
Measurement range -50-360mmHg
Channel 2 channels
Pressure transducer Sensitive :5 uV/V mmHg
Impedance range :300-3000 Ω
Pressure names ART, PA, CVP, RAP, LAP, ICP, P1, P2
Alarm range -10-300 mmHg
PR from IBP Range & Accuracy: 25-200bpm  ±1bpm or ±1bpm which is greater
201-350bpm ±2%
Resolution : 1bpm
Depth of Anesthesia (BIS)
EEG sensitivity +/- 475μV
Noise < 2uVp-p (1-150 Hz)
CMRR > 100 dB
Input impedance > 50mohm
Sample rate 1024 samples/s, 16 bits
Index and display update 0-100, filter 1-47 Hz, 1 sec. display update
EEG waveform ± 500 µV scaleable, filter 1-30 Hz, 3 sec. window length.                             
ESR 0-100%
EMG 0-100 arbitrary unit Curve and bar
Index trend 5 min and 60 min
Digital output Wireless BT interface (RFCOMM) 10 meters range
Alarms IoC high and low user selectable limits
Artifact rejection Automatic: user can disable.
Sensor impedance range 0 - 14kohm
EtCO2 (Main-stream / Side-stream )
Measurement range 0-150mmHg
Accuracy ±2mmHg(0-40mmHg)
±5% of reading(41-76mmHg)
±10% of reading (77-99mmHg)
Resolution 1mmHg
Sampling rate 70m1/min 100m1/min
Sampling rate accuracy 0.15 or 15m1/min
Start-up time
 
30 Sec. the module enters the warming up status after the start up.
1 minute later, it enters the ready-to-measure status.
Respiration rate 3-150 rpm
Respiration rate accuracy ±2BrPM (0-70BrPM)
±5BrPM (>70BrPM)
Response time
 
 
 
 

 
When measured with a neonatal water trap and a 2.5 m-long neonatal sampling line:
< 3.5 s @ 100 ml/min  
<4 s @ 70 ml/min
When measured with an adult water trap and a 2.5 m-long adult sampling line:
<5.5 s @ 100 ml/min  
<7 s @ 70 ml/min
Delay time
 
 
 
 

 
When measured with a neonatal water trap and a 2.5m-long neonatal sampling line:
<3 s @ 100 ml/min 
<3.5 s @ 70 ml/min
When measured with an adult water trap and a 2.5m-long adult sampling line:
<5 s @ 100 ml/min
<6.5 s @ 70 ml/min

Details:
F5 A8 12.1 Inch Medical Portable Clinic Diagnostic Multi Parameter Patient Monitor
F5 A8 12.1 Inch Medical Portable Clinic Diagnostic Multi Parameter Patient Monitor


Company Information:
F5 A8 12.1 Inch Medical Portable Clinic Diagnostic Multi Parameter Patient Monitor

F5 A8 12.1 Inch Medical Portable Clinic Diagnostic Multi Parameter Patient Monitor
F5 A8 12.1 Inch Medical Portable Clinic Diagnostic Multi Parameter Patient Monitor

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory
Management System Certification
ISO 9001, ISO 13485
Import & Export Mode
Have Own Export License