• Hb001 Hospital ICU Equipment Baby and Infant Radiant Warmer Baby Incubator
  • Hb001 Hospital ICU Equipment Baby and Infant Radiant Warmer Baby Incubator
  • Hb001 Hospital ICU Equipment Baby and Infant Radiant Warmer Baby Incubator
  • Hb001 Hospital ICU Equipment Baby and Infant Radiant Warmer Baby Incubator

Hb001 Hospital ICU Equipment Baby and Infant Radiant Warmer Baby Incubator

Feature: Double Inclined Plane Organic Glass
Full Open Front Door: Yes
X-ray Cassette Under The Bassinet: Yes
Certficates: ISO, Ce
OEM&ODM: Available
Suitable Temperature: Microcomputer Control Precisely
Customization:
Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
HB001
Excellent Performance Cleaning
Easy to Clean and Sterilize
Oxygen Concentration Analyzer
Detect The Baby Cabin Oxygen Concentration
Transport Package
Wooden Package
Specification
ISO, CE
Trademark
WANROOEMED
Origin
China
HS Code
9018909000
Production Capacity
500set/Month

Product Description

Hb001 Hospital ICU Equipment Baby and Infant Radiant Warmer Baby Incubator Hb001 Hospital ICU Equipment Baby and Infant Radiant Warmer Baby Incubator
Feature:
The world trend of double inclined plane organic glass
Many countries adopt double inclined plane organic glass, which gives a visual sense of relaxed ease, a full range of observed objects without deformation and reflection, conveniently for medical staff monitor care.
Full open front door
Large front door, all the flip open, easy to operate for medical staff and easy to get in and out for infant.
Suitable temperature for infant
Temperature system adopts microcomputer control, high precise, small temperature fluctuation
Inclination of large bassinet is adjusted steplessly.
infant bassinet tilt baby bed can be used for about 8 degrees of tilt, bed area  is 10% larger than the average incubator.
Two-way pulling out of the bassinet
bassinet can b e pulled out smoothly from the front door or right side door, to facilitate neonatal medical care.
 X-ray cassette under the bassinet
China's first infant incubator with X-ray radiography, radiography cassette underneath beds, non-metal transparent window allow X-ray pass, no leaving the infant incubator for X-ray photograph.
Large display window for multi-parameters
Setting value and real value display at the same time, medical staff  can know the infant incubator operations from long distance by large LED digital tube.
Concealed humidification devices
Incubator is installed the spray humidifier which is a national initiative, the humidity can be set freely, and controlled by microcomputer, humidity in the baby's hood can be accurately maintained at the set value within ± 5%.
High-quality air filter net
Superior performance of the filter adsorption can make air into the incubator more clean, and easy to clean replacement.
Excellent performance cleaning and disinfection
Whole up-body overturned function make the medical staff easy to clean and sterilize.
Failure alarm indication
Incubator security be guaranteed fully, the battery voltage alarm and water alarm is a national initiative.
RS480 Computer interface
Communication interface far distance control available.
    

Optional:
oxygen concentration analyzer
Hypoxic, or oxygen excess are detrimental to infant training and development, the oxygen concentration analyzer can detect the baby cabin oxygen concentration
Up blue-light box
can be cured in blue-light
Down blue-light box
can be cured in blue-light

Technical Specifications:
Item specifications
heating voltage ≤300W±10%
Incubator temperature control range 25-37 °C
Skin temperature control range 34-37.5 °C
Skin temperature sensor accuracy ≤ 0.3 °C
Bed surface temperature average ≤1.5 °C
Humidity accuracy ≤10%
Humidity display range 30-99%
Temperature fluctuation ≤0.5 °C
Temperature rise time <40min
Temperature deviation alarm range For incubator:  ±3 °C
For skin:  ±1 °C
indoor noise of incubator ≤45dB
Alarm noise Indoor:  ≤70dB
Outdoor:  ≥60dB
overtemperature alarm ≤38 °C
Second overtemperature alarm ≤40 °C
Alarm of sensor fault response time <4s, Continuous alarm
Power failure alarm response time <5s, Continuous alarm
Air blower stopping alarm, air-duct block alarm response time <30s, Continuous alarm
Lack water alarm Inlet tube water level is under the sign of "MIN"
Upper-body overturn angle 30 °C
Electric lifting distance 150mm
Inclination of large bassinet 0-8°stepless
Temperature display mode LED digital display
Infant incubator body material Organic glass, double walls hood, cabinet case
Oxygen concentration measurement(optional) 0 ~ 100%
Panel automatically locked yes
Operation window No less than 5 pcs, with auxiliary air sensor
Panel feature Touch panel, water-proof, sensitivity and reliability
Low battery alarm <4.5V
Safety performance According with class I, IEC601-1, 1998.GB9706.1-1995 and GB11243-2000
Hb001 Hospital ICU Equipment Baby and Infant Radiant Warmer Baby Incubator
Hb001 Hospital ICU Equipment Baby and Infant Radiant Warmer Baby Incubator
Hb001 Hospital ICU Equipment Baby and Infant Radiant Warmer Baby Incubator

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory
Management System Certification
ISO 9001, ISO 13485
Import & Export Mode
Have Own Export License