WS Horizontal Pulsating Vacuum Steam Sterilizer Autoclave for Pharmaceutical Factory and Scientific Research Laboratory
Description:
1. The main body consists of an inner layer and an outer layer. The inner cavity is made of high quality acid resistant 304 stainless steel. Automatic welding, one-time molding. Horizontal circular chamber + jacket structure, safety, heat preservation, drying effect is the best.
2. Adopt plate type cogging type + motor or manual locking door structure, low fault, reliable; Double doors optional. Simple and safe operation.
3. The door seal is pneumatic or self-inflating. The sealing strip is made of excellent heat-resistant silicone rubber with long service life.
4. The control system adopts touch screen and PLC to ensure stable operation and correct temperature detection.
5. Water, pulse (special for vacuum system), heating, sterilization, drying process is fully automatic, without manual adjustment.
6. Built-in high quality vacuum pump, to ensure effective air exclusion, to obtain the best saturated steam (vacuum system). Unique pulse vacuum drying process (special for vacuum system), residual moisture less than 0.2%. 1~6 pulses, -0.09mpa (-0.9bar) vacuum, to ensure effective air exclusion to obtain the best saturated steam (vacuum system special)
7. Built-in high efficiency steam generator, microcomputer temperature control, time saving
8. Pipeline system is optimized design,SUS304 pipeline, clamp type quick loading mode. All piping, fittings and components are designed and installed on one side for greater convenience. Repair and maintenance. The sterilizer can be mounted against a wall, or two sterilizers can be used simultaneously. Maintain space to save installation space.
9. Control system: HMI man-machine interface, touch screen + microcomputer.
Built-in micro printer, record the entire sterilization information. Equipped with standard equipment verification interface;
11. F0 value and temperature time double guarantee sterilization effect, with perfect sterilization record;
12. With program selection, parameter setting, equipment operation, report processing and other functions, traceable;
13. Multiple safety protection measures; Well-designed fault warning system, fault information real-time display on the touch screen. After the sterilization cycle is complete, a beep sound will be emitted and a message will be displayed on the touch screen.
14. Sterilization process: fabric, instrument, liquid, BD, pressure holding test, custom multiple procedures;
Safety protection:
1. heater protection;
2. prevent dry burning;
3. safety interlocking door;
4.over temperature protection;
5. overvoltage protection;
6. automatic release safety valve;
7. electrical safety protection device.
Main Technical Parameter | |
Design pressure | -0.1~0.3Mpa |
Design temperature | 144ºC |
Working pressure | 0.245Mpa |
Vacuum | -0.086Mpa |
Working Temperature | 105~138ºC |
Temperature Equilibrium | < +2.0ºC |
Water Pressure | 0.1-0.2Mpa |
Compessed air pressure | 0.4-0.7Mpa |
Steam Pressure | 0.3-0.7Mpa |
Power vltage | Three-phase five-wire |
AC 380V 50Hz |
Model&Parameter(Without Pulse Vacuum/With Pulse Vacuum ) |
|||||
Model |
Overall Dimensions L*M*H(mm) |
Chamber Size (Φ*L)mm |
Steam Consumption (KG) |
Water Consumption(KG) |
Net Weight(KG) |
WS-80D |
990x640x1680 |
Φ420x580 |
≤9/≤10 |
≤30 |
220/(250/280) |
WS-100D |
1160x650x1680 |
Φ420x750 |
≤10/≤11 |
≤30 |
250/(280/310) |
WS-120D |
1290x650x1680 |
Φ420x880 |
≤11/≤12 |
≤30 |
280/(310/340) |
WS-150D |
1290x690x1680 |
Φ472x880 |
≤12/≤13 |
≤190 |
350/(370/410) |
WS-200D |
1560x690x1680 |
Φ472x1150 |
≤13/≤15 |
≤190 |
370/(400/440) |
WS-300D |
1430x850x1760 |
Φ620x995 |
≤18/≤20 |
≤200 |
450/(480/530) |
WS-400D |
1755x850x1760 |
Φ620x1320 |
≤22/≤25 |
≤200 |
510/(540/590) |