Customization: | Available |
---|---|
Classification: | Physiological Functions of Diagnosis and Monitoring Equipment |
Type: | Patient Monitor |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Physical Specifications |
||
Dimension and weight | Dimension | 375mm(W)*330mm(H)*180mm(D) |
Weight | standard configuration: 4.4 kg | |
Operation environment | Power requirements | AC 90-300V, 50/60HZ, 60W |
Power | 90VA | |
Temperature | 0-40ºC | |
Humidity | 0-93% non-condensing | |
Safety | Meet the requirements of IEC60601 series | |
Patient range | Adult, neonate and pediatric patients | |
Performance Specification | ||
Display | 12.1 inch (800 x 600 pixel) color TFT LCD rolling and refreshing waveform display | |
Display mode | Standard, large font, trend table, full lead ECG, Oxy CRG,NIBP trend | |
Interface |
Parameter cable interface AC power input socket |
|
Battery | Rechargeable battery, 2.2 Ah 12V | |
Alarm indicator | Visual on-display and integrated alarm light Audible alarm and personated voice reminding alarm |
|
Data storage |
240 hours monitoring data 1024 NIBP records storage 1024 alarm event |
|
Printer |
Built-in 50mm thermal printer (option), 2 traces, print speed 25mm/s & 50mm/s print width:50mm |
|
ECG | ||
Leads type | 3(option)/5-lead : I, II, III, aVR, aVL, aVF, V | |
Sweep speed | 12.5mm/s, 25mm/s 50mm/s | |
Gain selection | ×0.25, ×0.5, ×1, ×2 | |
ECG waveform | 1 channels | |
Operation mode | Diagnostic, monitor, surgery | |
Heart rate range | 0 -300bpm | |
Accuracy | 1bpm or ±1% whichever is great | |
Alarm range | Audible and visual alarm, adjustable | |
ST/ arrhythmia | Real time S-T segment detection, pace detection and arrhythmia analysis | |
Protection | Against electrosurgical interference and defibrillation | |
Respiration (RESP) | ||
Method | Thoracic impedance | |
Operation mode | Auto | |
Measurement range | Adult: 0-120BrPM; neonatal /pediatric: 0-150BrPM | |
Apnea alarm | Yes | |
Alarm | Yes, audible and visual alarm ,alarm events recallable | |
NIBP | ||
Method | Automatic oscillometric | |
Operation mode | Manual/Automatic/STAT |
Auto measure time | Adjustable | |
Measurement unit | mmHg / kPa selectable | |
Test interval | 1-480 minutes | |
Measurement range |
Adult: 0-300 mmHg ; Child: 0-240 mmHg ; Infant: 0-150 mmHg |
|
Over-pressure protection | Double safety protection | |
Accuracy of blood pressure measurement | The mean error shall be less than±5mmHg the standard deviation shall be less than 8mmHG |
|
Resolution | 1 mmHg | |
SPO2 | ||
Measurement range | 0%-100% | |
Resolution | 1% | |
Accuracy | ±2% (70-100%, adult/pediatric, non-motion ) ±3% (70-100%, neonate, non-motion ) ±3% (70-100%, adult/pediatric/neonate, motion ) 0-69% unspecified |
|
Alarm range | 1-100% | |
Pulse rate | Pulse range: | 20-300bpm |
Accuracy: | ±3bpm(non-motion) ±5bpm(motion ) |
|
Temperature (TEMP) | ||
TEMP range | 0-50ºC | |
Resolution | 0.1 ºC | |
Accuracy | ±0.1ºC (excluding the sensor) | |
Channel | Single channel. |