Portable First Aid Aed Biphase Automatic External Defibrillator with ECG Monitor and Pacer

Product Details
Customization: Available
Classification: Physiological Functions of Diagnosis and Monitoring Equipment
Type: Aed

360° Virtual Tour

Diamond Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Experienced Team
The supplier has 6 foreign trading staff(s) and 5 staff(s) with over 6 years of overseas trading experience
Customization from Samples
The supplier provides sample based customization services
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO13485:2016
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (16)
  • Portable First Aid Aed Biphase Automatic External Defibrillator with ECG Monitor and Pacer
Find Similar Products
  • Overview
  • Product Parameters
  • Company Profile
Overview

Basic Info.

Model NO.
Defi Xpress
Certification
CE, ISO13485
Group
Adult, Child
Screen Size
8 Inch
Maximum Energy Manual Mode
360j
ECG Monitoring
3-Lead / 5-Lead
Battery
Built-in
Specification
49*49*54CM
Trademark
ROOETECH
Origin
China
HS Code
94029000
Production Capacity
5000set/Sets / Month

Product Description

Defi Xpress Portable First Aid AED Biphase Automatic External Defibrillator with ECG Monitor and Pacer
Portable First Aid Aed Biphase Automatic External Defibrillator with ECG Monitor and Pacer
Features:
1.  With manual defibrillation, automatic external defibrillation (AED), ECG monitoring and other functions, is a professional dual-phase defibrillation monitor, suitable for hospitals and clinics;
2.  8-inch screen showing HR, Lead/Pads, On/Off Alarm, SpO2, AED Functions and Prompts, Alarm Selection and Limits, Delivered Energy.
3.  Automatic analysis of external defibrillation, can automatically select energy, provide screen display and voice prompt.
4.  Built-in battery, can be recharged multiple times.
5.  Defibrillation output waveform: biphase waveform
6.  50mm thermal printer provides defibrillation record.
7.  The maximum energy in manual mode is 360J
8.  3-lead / 5-lead ECG monitoring, displayed on the screen, providing alarm tips.
9.  Optional cardiac pacing function.

 
Product Parameters

 

Specification Pacer (Optional)
Type VVI
Pulse Type rectangular,constant current
Pulse Amplitude 0 to 180 mA±10% or 5 mA (whichever is greater).
Pacing Rate Variable from 30 ppm to 180 ppm +1.5% (increments or decrements by a value of 2 ppm)
Multi-Function Electrode (MFE)Pads multipurpose defibillation/pacing electrodes
Pause Pacing pulse frequency reduced by a factor of 4 when activated.
Refractory Period NC(VVI demand do not have this specification)
Pulse Width (20+ 1.5 ms)
Output Protection Fully defibrillator protected and isolated
Specification EtCO2 (Optional)
Type of sensor By-pass
Technical principle Non-dispersive infrared gas analysis NDIR
Storage condition -40 °C to 70°C,<90% RH, non-condensing
Operating conditions 5°C to 50 °C, 10 to 90% RH, non-condensing
Ambient pressure 55-115kPa
Power supply 5V±5% (max ripple 200 mVp-p)
TDP Typical value 120mA Excursion calibration typical value 280mA
Range 0-19.7% (0-150mmHg,or 0-20kPa)
Resolution 0.1mmHg
Accuracy 0-40mmHg±2mmHg
41 - 70 mmHg±5% of reading
71 - 100 mmHg±8% of reading
101 - 150 mmHg±10% of reading
For more parameters, please send us your enquiry directly

Details:
Portable First Aid Aed Biphase Automatic External Defibrillator with ECG Monitor and Pacer

 
Company Profile

Company Information:

Portable First Aid Aed Biphase Automatic External Defibrillator with ECG Monitor and Pacer
Portable First Aid Aed Biphase Automatic External Defibrillator with ECG Monitor and Pacer
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier