| HB103 | HB102 | HB101 | HB100 | |
| Mattress to Hood | 450mm | 450mm | 450mm | 410mm |
| Observation side of hood | Two incline | Two incline | Two incline | Two incline |
| Operate port | 6 | 6 | 6 | 4 |
| Front access panel | 826*310mm | 826*310mm | 826*310mm | 826*280mm |
| Mattress tray size | 630*360mm | 630*360mm | 630*360mm | 630*360mm |
| Power supply | ≤400VA | ≤400VA | ≤400VA | ≤400VA |
| Temperature controlled by microcomputer | Air and skin temp Air temp |
Air and skin temp Air temp |
Air temp | Air temp |
| Air temp control range | 20ºC-37ºC | 20ºC-37ºC | 20ºC-37ºC | 20ºC-37ºC |
| 37ºC-39ºC | 37ºC-39ºC | 37ºC-39ºC | -------- | |
| Skin Temp control range | 30ºC-37ºC | 30ºC-37ºC | ----------- | ------------ |
| 37ºC-38ºC | 37ºC-38ºC | ------------ | ------- | |
| Skin Temp sensor accuracy | ≤0.3ºC | ≤0.3ºC | ------------ | ------- |
| Humidity display range | 5%-99% | ------------- | --------- | -------------- |
| Temperature fluctuation | ≤0.5ºC | ≤0.5ºC | ≤0.5ºC | ≤0.5ºC |
| Mattress temperature uniformity | ≤0.8ºC | ≤0.8ºC | ≤0.8ºC | ≤0.8ºC |
| Temperature rise time | ≤30min | ≤30min | ≤30min | ≤30min |
| Noise level within hood environment | ≤55dB | ≤55dB | ≤55dB | ≤55dB |
| Alarms | ||||
| Power failure alarm | yes | Yes | yes | yes |
| Fan failure alarm | yes | Yes | yes | yes |
| Sensor failure alarm | yes | Yes | yes | yes |
| High air temp alarm | +1.5ºC | +1.5ºC | +1.5ºC | +1.5ºC |
| Low air tem alarm | -2.5ºC | -2.5ºC | -2.5ºC | -2.5ºC |
| High skin temp alarm | +1.0ºC | +1.0ºC | ---- | --- |
| Low skin tem alarm | -1.0ºC | -1.0ºC | ----- | |
| Over air tem alarm | ≤38ºC, ≤40ºC | ≤38ºC, ≤40ºC | ≤38ºC, ≤40ºC | ≤38ºC |
| Over skin tem alarm | ≤38ºC, ≤39ºC | ≤38ºC, ≤39ºC | ≤38ºC, ≤39ºC | -- |
| System failure alarm | yes | yes | yes | -- |
| Alarm silence function | yes | yes | yes | --- |
| Operational condition | ||||
| Environment temperature | +20ºC-+30ºC | +20ºC-+30ºC | +20ºC-+30ºC | +20ºC-+30ºC |
| Environment relative humidity | 5%-99% | 5%-99% | 5%-99% | 5%-99% |
| Environment air velocity of flow | <0.3m/s | <0.3m/s | <0.3m/s | <0.3m/s |
| Others | ||||
| RS232 interface | yes | yes | yes | yes |
| Railing | yes | yes | yes | ---- |
| Infant bed tilt adjustment | ±10° step less | ±10° step less | ±10° step less | --------- |
| Max load of mattress tray | 10kg | 10kg | 10kg | 10kg |
| IV Pole Max load | 2kg | 2kg | 2kg | 2kg |