• High Quality Yg Pulse Vacuum Dry Sterilizer for Medical Waste, Hospital Pollutants, Expired and Broken Medicines Disposal
  • High Quality Yg Pulse Vacuum Dry Sterilizer for Medical Waste, Hospital Pollutants, Expired and Broken Medicines Disposal
  • High Quality Yg Pulse Vacuum Dry Sterilizer for Medical Waste, Hospital Pollutants, Expired and Broken Medicines Disposal
  • High Quality Yg Pulse Vacuum Dry Sterilizer for Medical Waste, Hospital Pollutants, Expired and Broken Medicines Disposal
  • High Quality Yg Pulse Vacuum Dry Sterilizer for Medical Waste, Hospital Pollutants, Expired and Broken Medicines Disposal
  • High Quality Yg Pulse Vacuum Dry Sterilizer for Medical Waste, Hospital Pollutants, Expired and Broken Medicines Disposal

High Quality Yg Pulse Vacuum Dry Sterilizer for Medical Waste, Hospital Pollutants, Expired and Broken Medicines Disposal

Theory: Pressure Steam
Type: Pressure Steam Sterilization Equipments
Certification: CE, FDA
Electric Tension: 380V
LCD Display: With LCD Display
Ultra High Temperature Alarm: Ultra High Temperature Alarm
Customization:
Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
YG Series
Sterilization Information Recording and Printing
Sterilization Information Recording and Printing
Material
Stainless Steel
Chamber Material
316 Stainless Steel
Outside Shell
304 Stainless Steel
Printer
Included
PLC Brand
Simens
Working Modes
Customized, and with Several Standard Procedure
Door
Two Doors for Loading and Unloading
Control Mode
PLC
Chamber Volume
120/250/360/600/800/1200/2500/5000L for Choosing
Steam Generator
If Volumn Less 600L, Can Be Equipped
Sterilization Item
Surgical Instrument, Medical Cloths etc
Transport Package
Export Carton Package
Specification
CE, ISO
Trademark
WANROOEMED
Origin
China
HS Code
84192000
Production Capacity
1000 Sets/Month

Product Description

High Quality Yg Pulse Vacuum Dry Sterilizer for Medical Waste ,Hospital Pollutants ,Expired and Broken Medicines Disposal
High Quality Yg Pulse Vacuum Dry Sterilizer for Medical Waste, Hospital Pollutants, Expired and Broken Medicines Disposal

Description:

1. With double jacket construction, complete recessed jacket should be provided around the chamber to avoid steam condensation and promotion, and appropriate temperature distribution. It can be heated evenly to prevent the material from uneven heating.
2. Chamber: the chamber is made of SUS316L, according to mechanical and chemical treatment, the surface of the chamber is bright, the Angle of the chamber is arc transition, no cleaning dead Angle, corrosion resistance. Two stainless steel guide rails shall be provided in the chamber as the rails for the loading car.
3. The insulation layer is made of aluminosilicate, the best insulation material, and the equipment is rectangular with stainless steel decorative cover.
4. The door:
- Autoclave design is straight-through (double door) autoclave. Front and rear doors won't open at the same time.
- The door seal is inflatable, pressurized with compressed air and can withstand chamber temperature and pressure.
- The door shall have a safety mechanism to prevent the door from opening when the chamber is hot or pressurized or when pressurized in an autoclave.
- Sterilization cycle can only be started after the door is completely closed and locked.
5. Pipeline system consists of filter, vacuum pump, pneumatic valve and so on.
- Air filters are Pall brand. Excellent performance, no medium fracture or pollution unloading.
- Vacuum pump: Autoclave includes liquid ring vacuum pump to obtain vacuum in the chamber, ensuring proper air removal for excellent sterilization.
- Angle pneumatic valve: strong on/off valve, without any error, remote compressed gas control. Stainless steel clamp seat for inner cabin.
6. Control system:
-PLC + HMI control +Micro- data printing, should be able to default one or more sterilization cycles. Electrical equipment system adopts domestic or imported parts, its performance is stable and reliable.
- Advanced control function, large storage capacity, trouble-free operation time up to 50,000 hours.
- Primary controller system: You can set the user name and password, and set different users to access the system. It has three interface functions: manager, user and maintainer. The administrator can set the password according to different levels of use, to ensure the use of security, to prevent improper operations or modify the program to bring about experiments.
- When the automatic controller is in failure, the safety device keeps the sterilization chamber pressure safe under the atmosphere pressure to the back of the state and allows the loading door to be opened.
- Manual operations can be done using access control tools for maintenance, testing and emergency needs.
7. Touch screen:
- Display working process parameters, simple control, easy to operate.
8. The interface has the following functions:
- Display screen shows sterilization cycle status, time, pressure, temperature, double door density, operation record, printing and other processes.
Printer: real-time output can be realized by micro needle printer, which can easily output "pressure, temperature, time, F0 value" and other parameters and curves.
- The autoclave has an emergency stop mechanism designed to immediately stop all physical movement of the device.
- Fixed GMP validation connector can provide GMP validation for customers free of charge.

Application range:
Sterilizer is used to sterilize medical waste. Medical waste is mainly caused by hospital, health and epidemic prevention units, patient sanosa, medical research units, etc., including: hospital clinical infectious waste, including patient surgical or corpse waste (such as tissue, contaminated materials and Instruments, etc.) Such as abandoned equipment, test tubes, filters, aprons, gloves, etc.); clinical, teaching, research and other medical activities containing colonies and abrasion-containing waste and infected animal corpses; infectious ward All waste (such as excrement, waste applications, domestic garbage and any other waste equipment, waste materials, waste materials); hospital produced, including waste needles, waste skin injection needles, scrap-of-cuts, scrap surgery knives , Waste transporter, waste surgical saw, crushing glass, etc.; sludge produced by hospital wastewater; expired drugs and chemical waste.

Waste Dressing Medical Glove Syringe
Infusion Set Blood transfusion apparatu Test Tube
Filter Apron Glove
Waste Needle Scalpel Surgical Saw
Broken Glass Expired Drug Ampoule
Other medical waste
Quality system:
The sterilizer is designed and manufactured in accordance with ISO 9001-2000 and ISO 13485-2003 quality management system.
Environmental system:
The supply of tap water or frozen water can reduce the amount of water of up to 90%, making your facilities more environmentally friendly, more cost effective.
Environmentally handled environmental treatment for distilled water and discharged gas, discharging non-pollution, zero infection.
Safety system:
Sterilizer has multiple safety structures, including overpressure protection, low water protection, door lock system, overload, and short-circuit protection to ensure safe operation.
Vacuum system:
The vacuum system is used to handle cold air and keep the cavity room temperature is uniform. All air leaves the chamber before sterilization is considered to have high infectivity and air is sterile.
The vacuum system of the sterilizer is mainly composed of a liquid ring vacuum pump, vacuum valve, and a pipeline. Among them, the vacuum pump is a key component. The vacuum system has the advantages of stable operation, small sound, high vacuum, and fast suction, ensuring sterilization effect and overall performance. The built-in vacuum pump produces a powerful vacuum to ensure proper air removal to achieve excellent sterilization.
Sterilization procedure:
- Automatic and manual operation methods;
- Automatic mode of operation:
Microbial inactivation:
The number of microorganisms after sterilization is reduced to less than 10-6.


Specification:
Design pressure 0.245Mpa   Vacunm -0.095Mpa
Working Pressure 0.22Mpa   Steam Source Pressure 0.4-0.6Mpa
Design Temperature 139ºC   Water Source Pressure 0.1-0.3Mpa
Working Temperature 134ºC   Compressed Air Pressure 0.5-0.7Mpa
Specifications Overall Dimensions Chamber Size Steam Consumption Power Water Consmption Net Weight
Model L*M*H(mm) L*W*H(mm) (kg/cycle) (KW) (kg/cycle) (kg)
  Single/Double Door          
YG-0.1 825*1080*1600 630*400*480 15 1 80 380
YG-0.25 895*1220*1720 760*600*600 20 1.5 150 650
YG-0.36 1195*1220*1720 1000*600*600 25 1.5 150 760
YG-0.6 1245*1300*1880 1050*680*850 30 2 200 1100
YG-0.8 1595*1300*1880 1400*680*850 35 3 250 1300
YG-1.2 1695*1370*1960 1500*750*1100 40 3 300 1900
YG-2.5 3195*1370*1960 3000*750*1100 75 4.5 450 2800
YG-5.0 3635*1800*2200 3400*1000*1500 150 7.5 600 4500
Details:
High Quality Yg Pulse Vacuum Dry Sterilizer for Medical Waste, Hospital Pollutants, Expired and Broken Medicines Disposal
High Quality Yg Pulse Vacuum Dry Sterilizer for Medical Waste, Hospital Pollutants, Expired and Broken Medicines Disposal
Company Information:
High Quality Yg Pulse Vacuum Dry Sterilizer for Medical Waste, Hospital Pollutants, Expired and Broken Medicines Disposal
High Quality Yg Pulse Vacuum Dry Sterilizer for Medical Waste, Hospital Pollutants, Expired and Broken Medicines Disposal

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory
Management System Certification
ISO 9001, ISO 13485
Import & Export Mode
Have Own Export License