Customization: | Available |
---|---|
Type: | Anaesthesia Machine |
Certification: | CE, FDA, ISO13485 |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Ventilator Specifications | |
Modes of Ventilation | |
VCV | Volume Control Ventilation |
SIMV-V | Synchronized Intermittent Mandatory Ventilation-Volume |
SIMV-P | Synchronized Intermittent Mandatory Ventilation-Pressure |
MANUAL | Manual |
A/C | Assist/Control |
PCV | Pressure Control Ventilation |
PSV | Pressure Support Ventilation |
STAND-BY | STAND-BY |
PA-VC | Optional |
Ventilator Parameter | |
Working type | Electronic control, pneumatic driven |
Tidal Volume range | 10-1500ml |
Pressure range | 5-60 cmH2O |
Rispriation rate range | 1-100 bpm (1-40bpm under SIMV) |
l:E range | 4:1-1:8 |
Ptrigger range | -20-20 cmH2O (based on PEEP) |
Flow trigger | 0-15 L |
Minute volume range | >18UMin |
SIGH range | 0-5/100 |
System Standard | |
Hypoxic guard system | N2O cut-off valve, O2 concentration >25% |
Safety valve | <12.5kPa |
Fresh gas compensation | 25-75L/min |
Volume of CO2 absorber | 2L |
Flow meter | E-flowmeter |
0.1-15L/min O2, 0.1-15L/min N2O, 0.1-15L/min air | |
Vaporizer | 2 Selectetac, maximum 2 mounts |
(Isoflurane/Enflurane/Sevoflurane/Halothane) | |
Monitoring | |
Display graphics | Waveforms of P-T, F-T, V-T, loops of P-V,V-F, F-P(Zoom in/out, |
comparison, freeze) | |
Types | VT, minute volume range, airway pressure, l:E range, lung compliance, |
plateau, O2 concentration, CO2 (optional),Anaesthetic Gas(optional) | |
Alarm Limits | |
Audio/Visual | No tidal volume, MV,Paw, F1O2 limitation O2, |
Air failure, AC power failure, Battery low | |
PEEP | |
Type | Integrated, Electronic control |
Range | OFF, 3-30cmH2O |
Auxiliary features | |
ACGO | Auxiliary Common Gas Outlet |
Yoke system(Pin-index) | Support 11 Lcylinder,O2/N2O |
AGSS | Anaesthetic Gas Scavenging Syetems(optional) |
Communication Interface | Ethernet, USB, VGA |
Worktable | Optional |
Patient Monitor | Optional |
E-anesthesia record | Optional |
Auxiliary Oxygen meter | Optional |