Hb-Yp910 Hospital Neonatal Care Infant Warmer Incubator
Reference FOB Price: | US $3,000.00-4,000.00 / Piece |
---|---|
Min. Order: | 1 Piece |
Type: | Baby Incubator |
---|---|
Function: | Infant Care |
Theory: | Electrotherapeutics |
Certification: | CE, ISO13485 |
LCD Display: | Without LCD Display |
Group: | Infant |
Basic Info
Model NO.
HB-YP910
Purpose
Infant Care
Oxygen Input Interface
Yes
SpO2
Optional
Humidity Control System
Yes
RS-232 Connector
Yes
Air Temperature Control Range
25-37degree
Operating Range
20 -30degree
LED Blue Light
Optional
Factory Location
1.5 Hours From Shanghai
Transport Package
Wooden Package
Specification
1085mm x 640mm x 915mm
Trademark
WANROOEMED
Origin
China
HS Code
9018909000
Production Capacity
500set/Month
Product Description
Hb-Yp910 Hospital Neonatal Care Infant Warmer Incubator
Brief Introduction:
Two control modes: Air mode and baby mode controlled by micro-computer
Humidity concentration display system
Humidity control system(for HB-YP920)
Set temperature, air temperature, baby temperature, humidity concentration are displayed separately;
>37°C temperature set function;
Failure alarm indication;
Embedded integrated sensor box
Integrated water reservoir in the shape of drawer(for HB-YP920);
Double wall hood, automatic air circulation device;
Inclination of bassinet is adjustable;
RS-232 connector;
Oxygen input interface;
DC motor.
Standard Configuration:
HB-YP910: The hood, the base, the mobile cabinet, the controller, I.V pole, tray; HB-YP920: Based on HB-YP910, with Humidity control system.
Optional Configuration:
Fixed neonate bilirubin phototherapy equipment model:HB XHZ-90 (with blue fluorescent lamps);
Fixed neonate bilirubin phototherapy equipment model: HBXHZ-90L (with LED blue lights);
Vertical height adjustment stand (VHA stand), Weighing system , SPO2 and Disposable skin temperature sensor.
Specification:
Power requirement: AC220V-230V/50Hz or AC110-120V/50-60Hz, 850VA ( HB-YP910 )
AC220V-230V/50Hz or AC110-120V/50-60Hz, 1000VA (HB-920)
Mode of control: Air mode and baby mode controlled by micro-computer
Air temperature control range: 25°C -37°C (override mode 37-39°C )
Baby temperature control range: 34-37°C (override mode 37-38°C )
Accuracy of skin temperature sensor: ±0.2°C
The temperature difference between incubator temperature and average incubator temperature (under steady temperature condition)≤0.5°C
Temperature uniformity≤0.8°C (mattress is on the horizontal position)
Inclination of the bassinet: ±12° la Noise inside hood: 45dB(A)
Failure alarm: over temperature alarm, deviation alarm, sensor failure alarm, fan motor alarm, power failure alarm, sensor box position alarm and system alarm. (HB-YP920 has low water alarm and tank position alarm)
Humidity display range: 0%RH-99%RH
Humidity control range: 0%RH-90%RH (for HB-YP920)
Accuracy of humidity display: ±5%RH(environment temperature is 25°C , environment humidity is 45%RH±5%RH)
Environmental temperature:
Operating range: 20 °C -30°C (Set temperature should be higher 3°C than the environment temperature)
Ambient air movement rate: <0.3m/s
Product Packaging:
Package: each unit is packed into two cartons
Dimension (Main body): 1085mm x 640mm x 910mm
(Cabinet): 1125mm x 665mm x 725mm
Gross Weight (Main body):63Kg (for HB-910)
66Kg(for HB-920)
(Cabinet):68Kg
Details: