F6 V2.0 LED Multi-Parameter Ambulance Equipment Medical Patient Monitor

Classification: Physiological Functions of Diagnosis and Monitoring Equipment
Type: Patient Monitor
Certification: CE, FDA
Group: Adult, Pediatric and Neonatal Patient
Power Requirements: 100-240V, AC: 47-63Hz
Size: 256(W) X 209(H) X 185(D)
Customization:
Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
F6 V2.0
Alarm Indication
Visual and Audible Alarm
Certficates
ISO, Ce
Battery
Bulit-in
Digital SpO2
with
Thermal Printer
Yes
Trolley/Wall Mount
Optional
Central Monitor System
Optional
OEM&ODM
Available
Transport Package
Export Package
Specification
CE, ISO
Trademark
WANROOEMED
Origin
China
HS Code
94029000
Production Capacity
1000 Sets/Month

Product Description

F6 V2.0 LED Multi-Parameter Ambulance Equipment Medical Patient Monitor
F6 V2.0 LED Multi-Parameter Ambulance Equipment Medical Patient Monitor
Features:
1. 7'' TFT  LCD display, high resolution
2. Built-in rechargeable battery
3. User-Friendly operational window
4. 60s full disclosure of ECG playback
5. 48 hours tabular and graphic trends & data storage
6. Digital SpO2, high capacity against interference of ESU, motion & low infusion
7. Isolated against defibrillation effect
8. Wireless or wire communicable with central station system
9. Parameter :  5 Lead ECG, RESP, Digital SpO2, NIBP, TEMP


Standard Configuration:
SpO2, NIBP, PR, TEMP, RESP, ECG

Optional Configuration:
2-TEMP, Printer(50mm), Trolley/Wall mount, Nellcor SpO2, Central Monitor System
 
Technical specifications
-Safety: IEC60601(GB9706)
-Dimension: 256(W) x 209(H) x 185(D)
-Weight: 4Kgs (with battery)
-Power Supply: 100-240V; AC: 47-63Hz
12VDC
-Alarm Indication: Visual and audible alarm
ECG
-Lead selection:I, II, III, aVR, aVL, aVF  
-Gain: AUTO, 0.25x, 0.5x, 1.0x, 2.0x, 4.0x
-Input impedance: ≥5MΩ(d.c.-60Hz)
Common Mode Rejection Ratio: ≥85dB(diagnostic mode)
≥105dB(monitoring & surgical mode)
Bandwith: 0.5-40Hz(monitoring mode)
         0.05-120Hz(diagnostic mode) 
         1-25Hz(surgical mode)
Protection: Segregation breakdown voltage 4000VAC, 50/60Hz
Resistant to high-frequency electrome, myoelectricity, AC, drifting interference
Indication of Detachment of electrodes: Available
Playback of Cardiogram: Available
Scanning Speed: 12.5mm/s, 25mm/s, 50mm/s
Heart Rate Range: 10-300BPM
Accuracy: ±1BPM
NIBP
-Method: Automatic oscillmetry
-Operation Modes: Singles(manual), Cycle(automatic), Rapid(continuous)
-Measurement: Systolic pressure/diastolic preesure/mean
Range: Adult: 10-270mmHg
Pediatric: 10-235mmHg
Neonatal: 10-135mmHg
Unit: mmHg/Kpa selectable
Auto Measurement:  1, 2, 3, 4, 5, 10, 15, 20, 30, 45, 60, 90 minitues, 2, 4, 8 hours
600 groups of NIBP measuring data review
RESP
Method: Impedance Measurement
Measuring Range: 0-120 bmp
 
Alarm Limit: 0-120 bmp, upper and lower limit continuously adjustable
Apnea alarm: Available
Digital SpO2(Pulse Oximetry)
Range: 0-100%
Accuracy:±2(70%-100%)
Unspecified(0-34%)
Range&Accuracy of pulse rate: 25-250BPM±1BPM
TEMP
Channel" 0-100%
Range:0-50ºC
Unit: Celsius, Fahrenheit
Resolution: 1ºC
Accuracy: ±0.1ºC(25ºC-50ºC)
Environment Conditions:
Temperature:
Operation: 0ºC-50ºC
Storage/Transportation: -40ºC-70ºC
Humidity:
Operation: 10 % -95% noncondensing
Storage/Transportation: 0%-93%  noncondensing
Atmospheric Pressure:
Operation: 700-1060hPa
Storage/Transportation: 500-1060hPa


Company Information:
F6 V2.0 LED Multi-Parameter Ambulance Equipment Medical Patient Monitor
F6 V2.0 LED Multi-Parameter Ambulance Equipment Medical Patient Monitor

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory
Management System Certification
ISO 9001, ISO 13485
Import & Export Mode
Have Own Export License