• F5 China Suppliers Hospital Medical Equipment Emergency 12.1 Inches Patient Monitor

F5 China Suppliers Hospital Medical Equipment Emergency 12.1 Inches Patient Monitor

Classification: Physiological Functions of Diagnosis and Monitoring Equipment
Type: Patient Monitor
Certification: CE, FDA
Group: Adult, Pediatric and Neonatal Patient
Quality: ISO, China FDA,CE
Power Requirements: AC 100-240V, 50/60Hz, 60W
Customization:
Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
F5 A8
OEM&ODM
Available
Display Mode
Standard, Big Font, Trend Table, Full-Lead ECG, Ox
Size
340mm(W)*280mm(H)*130mm(D)
Battery
1 Internal Large Capacity Rechargeable Lithium Bat
Transport Package
Wooden Export Package
Specification
CE, ISO
Trademark
WANROOEMED
Origin
China
HS Code
94029000
Production Capacity
500 Sets/Month

Product Description

F5 China Suppliers Hospital Medical Equipment Emergency 12.1 inches Patient Monitor 
F5 China Suppliers Hospital Medical Equipment Emergency 12.1 Inches Patient Monitor
Features:

1. 12.1' color TFT LED screen supports display max. 8 waveforms
2. Visual On-display and integrated alarm light
3. Display mode: standard, large font, trend table, OxyCRG, full leads ECG
4. Arrhythmia analysis and real-time S-T segment analysis and pacemaker detection
5. Drug calculation, titration table
6. Suitable for monitoring adult, pediatric and neonatal patient.
7. Extended advance function: 2IBP, Depth of Anesthesia, EtCO2 , Nellcor SpO2

Standard Configuration:
Anti-glare screen, Large capacity rechargeable battery,  3/5-Lead ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature
Optional Configuration:
1. Dual IBP, Nellcor SpO2, MASIMO SpO2, Depth of Anesthesia Monitoring Module, EtCO2 (Main-stream/Side-stream)
2. Thermal printer (50 mm)
3. Pediatric / neonatal accessories: reusable NIBP cuff & SpO2 probe; disposable NIBP cuff & SpO2 probe
4. Central Monitoring System
5. Touch Screen
6. Trolley/Wall Mount
Physical Specifications
Dimension and weight Dimension 340mm(W)*280mm(H)*130mm(D)
Weight Standard configuration: 4 kg
Operation environment Power requirements AC 100-240V, 50/60HZ, 60W
Power 90VA
Temperature 0-40ºC
Humidity 0-93% non-condensing
Safety Meet the requirements of IEC60601 series
Patient range Adult, neonate and pediatric patients
Performance Specification
Display                         12.1' (800 x 600 pixel) color TFT LED screen
Display mode Standard, big font, trend table, full-lead ECG, Oxy CRG.
Interface Parameter cable interface
AC power input socket
Network interface
Battery 1 internal large capacity rechargeable lithium battery
Alarm indicator Visual on-display and integrated alarm light
Audible alarm
Data storage 108 hour trend graph
168 hour trend table
2 hour trend wave
1024 alarm events
Printer Built-in 50mm thermal printer (option),
3 traces, print speed 12.5mm/s & 25mm/s & 50mm/s  
Print width: 50mm
Net working Support connection to central monitoring station through LAN (TCP/IP) or wireless connection
ECG
Leads type 3/5 lead : I, II, III, aVR, aVL, aVF, V
Sweep speed 12.5mm/s, 25mm/s,50mm/s
Gain selection ×0.25, ×0.5, ×1, ×2, Auto
ECG waveform 2 channels
Operation mode Diagnostic, monitor, surgery
Heart rate range 0 - 350bpm
Accuracy 1bpm or ±1% whichever is great
Alarm range Audible and visual alarm, adjustable
ST/ arrhythmia Real time S-T segment detection, pace detection and arrhythmia analysis
Protection Against electrosurgical interference and defibrillation
Respiration (RESP)
Method Thoracic impedance
Operation mode Auto
Measurement range Adult: 0-120BrPM; neonatal /pediatric: 0-150BrPM
Apnea alarm Yes
Alarm Yes, audible and visual alarm ,alarm events recallable
NIBP
Method Automatic oscillometric
Operation mode Manual / Automatic / STAT
Auto measure time Adjustable
Measurement unit mmHg / kPa  selectable
Test interval 1-480 minutes
Measurement range Adult: 0-300 mmHg ;   
Child: 0-240 mmHg ;    
Infant: 0-150 mmHg
Over-pressure protection Double safety protection
Accuracy of blood pressure      measurement The mean error shall be less than ± 5mmHg
The standard deviation shall be less than 8mmHG
Resolution 1 mmHg
SPO2
Measurement range 0%-100%
Resolution 1%
Accuracy ±2% (70-100%, adult/pediatric, non-motion )
±3% (70-100%, neonate, non-motion )
±3% (70-100%, adult/pediatric/neonate, motion )
0-69% unspecified
Alarm range 1-100%
Pulse rate                       Pulse range: 0-350bpm
Accuracy: ±3bpm(non-motion)
±5bpm(motion )
Temperature (TEMP)
TEMP range 0-50ºC
Resolution 0.1 ºC
Accuracy ±0.1ºC  (excluding the sensor)
Channel Dual-channel. provide T1;T2; T
IBP
Measurement range -50-360mmHg
Channel 2 channels
Pressure transducer Sensitive :5 uV/V mmHg
Impedance range :300-3000 Ω
Pressure names ART, PA, CVP, RAP, LAP, ICP, P1, P2
Alarm range -10-300 mmHg
PR from IBP Range & Accuracy: 25-200bpm  ±1bpm or ±1bpm which is greater
201-350bpm ±2%
Resolution : 1bpm
Depth of Anesthesia (BIS)
EEG sensitivity +/- 475μV
Noise < 2uVp-p (1-150 Hz)
CMRR > 100 dB
Input impedance > 50mohm
Sample rate 1024 samples/s, 16 bits
Index and display update 0-100, filter 1-47 Hz, 1 sec. display update
EEG waveform ± 500 µV scaleable, filter 1-30 Hz, 3 sec. window length.                            
ESR 0-100%
EMG 0-100 arbitrary unit Curve and bar
Index trend 5 min and 60 min
Digital output Wireless BT interface (RFCOMM) 10 meters range
Alarms IoC high and low user selectable limits
Artifact rejection Automatic: user can disable.
Sensor impedance range 0 - 14kohm
EtCO2 (Main-stream / Side-stream )
Measurement range 0-150mmHg
Accuracy ±2mmHg(0-40mmHg)
±5% of reading(41-76mmHg)
±10% of reading (77-99mmHg)
Resolution 1mmHg
Sampling rate 70m1/min 100m1/min
Sampling rate accuracy 0.15 or 15m1/min
Start-up time 30 Sec. the module enters the warming up status after the start up.
1 minute later, it enters the ready-to-measure status.
Respiration rate 3-150 rpm
Respiration rate accuracy ±2BrPM (0-70BrPM)
±5BrPM (>70BrPM)
Response time


 
When measured with a neonatal water trap and a 2.5 m-long neonatal sampling line:
< 3.5 s @ 100 ml/min 
<4 s @ 70 ml/min
When measured with an adult water trap and a 2.5 m-long adult sampling line:
<5.5 s @ 100 ml/min 
<7 s @ 70 ml/min
Delay time


 
When measured with a neonatal water trap and a 2.5m-long neonatal sampling line:
<3 s @ 100 ml/min
<3.5 s @ 70 ml/min
When measured with an adult water trap and a 2.5m-long adult sampling line:
<5 s @ 100 ml/min
<6.5 s @ 70 ml/min

Details:
F5 China Suppliers Hospital Medical Equipment Emergency 12.1 Inches Patient Monitor

Company Information:
F5 China Suppliers Hospital Medical Equipment Emergency 12.1 Inches Patient Monitor
F5 China Suppliers Hospital Medical Equipment Emergency 12.1 Inches Patient Monitor
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory
Management System Certification
ISO 9001, ISO 13485
Import & Export Mode
Have Own Export License