• Mars K Hospital 10.4 Inches Medical Infant Detection Diagnosis Portable Ctg Fetal Doppler Monitor
  • Mars K Hospital 10.4 Inches Medical Infant Detection Diagnosis Portable Ctg Fetal Doppler Monitor
  • Mars K Hospital 10.4 Inches Medical Infant Detection Diagnosis Portable Ctg Fetal Doppler Monitor

Mars K Hospital 10.4 Inches Medical Infant Detection Diagnosis Portable Ctg Fetal Doppler Monitor

Certification: CE, FDA
LCD Display: With LCD Display
Group: Adult, Neonate and Pediatric Patients
OEM: Available
Patient Range: Adult, Neonate and Pediatric Patients
Battery: Internal Rechargeable Li-ion Battery Power
Customization:
Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
Mars K
Certificates
ISO,CE
Power Requirements
AC100-240V , 50/60Hz
Dimension
32cm (W)*26cm (D)*8cm (H)
Transport Package
Fetal Monitor Export Package
Specification
ISO, CE
Trademark
WANROOEMED
Origin
Jiangsu, China (Mainland)
HS Code
94029000
Production Capacity
1000 Set/Sets / Month

Product Description

Mars K Hospital 10.4 Inches Medical Infant Detection Diagnosis Portable CTG Fetal Doppler Monitor
Mars K Hospital 10.4 Inches Medical Infant Detection Diagnosis Portable Ctg Fetal Doppler Monitor


Features:
1. Folded 10.4 inches TFT LCD high-brightness screen
2. 12-crystal waterproof pulse Doppler transducer (optional), providing
wider beam area and more homogeneous signal, thus realizing better
performance for beside monitors than conventional transducers.
3. Event Marker makes it easy to annotate perceived fetal movements (FM),
or other events on the strip chart.
4. Fetal Movement Profile(FMP) detects and automatically records gross
fetal body movements
5. Heart rate offset mode makes it easy to visually distinguish between
the heart rates of twins by allowing you to offset the secondary FHR + 30BPM.
6. Heartbeat Coincidence recognition provides visual and audible indication
when it detects synchronous fetal or maternal heart-rate signals, indicating
that you may be monitoring a duplicate signal.
7.  Fetal heart rate alarm provides both audible and visual alerts if the heart rate
is outside of the user-defined high/low range.
8. Easy-to-load Z-fold paper stacks itself neatly upon exiting the recorder,
facilitating easy storage.
9. Internal Li-on battery power or AC power from external power supply.
10. Supporting TCP/IP or wireless connection to the central monitoring station
11. NST Report (Fetus health report)

 
Physical Specifications
Dimension and Weight Dimension 32cm (W)*26cm (D)*8cm (H)
Weight standard configuration: 2.8 kg
Operation Environment Power requirements AC100-240V , 50/60Hz
Power 50VA
Temperature 0-40ºC
Humidity 0-93% non-condensing
Fetal/Maternal Performance Specifications
Performance Specifications Display 10.4 inches (1024×768 pixel) color TFT -LCD
Indicator Visual on-display and integrated, alarm light, audible alarm
Battery Internal rechargeable Li-ion battery power
Alarm Visual on-display and integrated, alarm light, audible alarm
Memory 24-hours memory for fetal traces
150 groups patient data
Printer America standard/international standard  
Built-in thermal printer (paper width:110mm)
1/2/3cm/min real-time printing speed, fast print speed (stored traces)
Paper Z-fold, thermosensitive
Record Message ID, name, age, date, time, print speed etc
CMS Support connecting to central monitoring station through LAN (TCP/IP) or wireless connection
Fetal/Maternal Technical Specifications
Ultrasound (FHR) Measurement range US 30 to 240 bpm
Resolution Display 1bpm
Printer 1bpm
jitter@200 bpm ≤3bpm
Display update rate 0.25second
Beat to bea change(max.) for ultrasound 28bpm
US frequency 1MHz±5%Hz
TOCO Measurement method Strain gauge sensor element
Sensitivity 1 unit =2.5g
Resolution 1 unit
Measurement range 500 units
Baseline setting 0, 5,10, 15, 20 can be selective
Update rate 0.25 second
Auto offset correction 3 second after connecting the transducer
Auto zero adjust TOCO value is set to zero negative following a negative
Measure value for 5 seconds
Auto Fetal Movement (AFM) Technique Pulsed doppler ultrasound
Range  0-100%
Resolution 1%
Automatic fetal movement actograph
Manual fetal movement marker
Maternal NIBP(MNIBP) Operation mode Manual/automatic/ STAT
Measurement unit mmHg / kPa  selectable
Test interval 0-480 minutes
Accuracy Max.Std.deviation:8 mmHg(1.1kPa)
Max. mean Error: ±5mmHg(±0.7kPa)
Measurement range Systolic 30 to 270 mmHg(4 to 36 kPa)
Diastolic 10 to 245 mmHg(1.5 to 32kPa)
Mean 20 to 255 mmHg(2.5 to 34kPa)
Pulse rate range 20-250bpm
Over-pressure protection Yes
Maternal SpO2 (MSpO2) Measurement range 0%-100%
Resolution 1%
Accuracy ±2%
Pulse rate range accuracy ±3bpm                              
Details:
Mars K Hospital 10.4 Inches Medical Infant Detection Diagnosis Portable Ctg Fetal Doppler Monitor
Mars K Hospital 10.4 Inches Medical Infant Detection Diagnosis Portable Ctg Fetal Doppler Monitor
 Mars K Hospital 10.4 Inches Medical Infant Detection Diagnosis Portable Ctg Fetal Doppler Monitor

Company Information:

Mars K Hospital 10.4 Inches Medical Infant Detection Diagnosis Portable Ctg Fetal Doppler Monitor
Mars K Hospital 10.4 Inches Medical Infant Detection Diagnosis Portable Ctg Fetal Doppler Monitor
Mars K Hospital 10.4 Inches Medical Infant Detection Diagnosis Portable Ctg Fetal Doppler Monitor
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory
Management System Certification
ISO 9001, ISO 13485
Import & Export Mode
Have Own Export License