• Hospital Cssd Lab Polluted Consumables Disposal Medical Waste Harmless Treatment
  • Hospital Cssd Lab Polluted Consumables Disposal Medical Waste Harmless Treatment
  • Hospital Cssd Lab Polluted Consumables Disposal Medical Waste Harmless Treatment
  • Hospital Cssd Lab Polluted Consumables Disposal Medical Waste Harmless Treatment
  • Hospital Cssd Lab Polluted Consumables Disposal Medical Waste Harmless Treatment
  • Hospital Cssd Lab Polluted Consumables Disposal Medical Waste Harmless Treatment

Hospital Cssd Lab Polluted Consumables Disposal Medical Waste Harmless Treatment

Theory: Autoclave
Type: Pressure Steam Sterilization Equipments
Certification: CE, FDA
Electric Tension: 380V
LCD Display: With LCD Display
Ultra High Temperature Alarm: Ultra High Temperature Alarm
Customization:
Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
MCDS-250
Sterilization Information Recording and Printing
Sterilization Information Recording and Printing
Material
Stainless Steel
Chamber Material
316 Stainless Steel
Outside Shell
304 Stainless Steel
Printer
Included
PLC Brand
Simens
Working Modes
Customized, and with Several Standard Procedure
Control Mode
PLC
Sterilization Item
Medical Waste
Transport Package
Export Carton Package
Specification
CE, ISO
Trademark
ROOETECH
Origin
China
HS Code
84192000
Production Capacity
1000 Sets/Month

Product Description

Hospital CSSD Lab Polluted Consumables Disposal Medical Waste Harmless Treatment
Hospital Cssd Lab Polluted Consumables Disposal Medical Waste Harmless Treatment

Description:

Integrated autoclaves with shredders are an ideal solution for the safe disposal of infectious medical waste in hospitals and medical centers. First of all, MCDS is an integrated autoclave and shredder system that completes the sterilization and shredding process in a closed container, ensuring a clean environment and safe operation. Second, Autoclave Shredder has a complete automated processing process, which greatly reduces the dependence on professional operations teams. In addition, the compact yet practical design requires minimal installation space and basic infrastructure to operate. As a result, hazardous medical waste can always be disposed of in a timely manner in hospitals and healthcare centres, without the need for the transport of medical waste or the risk of secondary infection.

 

Medical waste treatment to meet the needs of medical centers, clinics, hospitals and laboratories of all sizes, generating from a few kilograms to several tons of biohazardous waste per day.

 

The medical waste sterilizer shredder converts all types of clinical by-products into sterile, inert and unidentifiable waste in its single, unique container. Once the biomedical waste has passed through hospital waste disposal, it can be considered as ordinary municipal waste without any biological risk to anyone handling it.

Features:

Pre Shredder:

1. Hard materials (such as glass, needle, scalpel, etc.) have the same crushing effect.

2. Adopt biaxial rotary shear crusher, the blade material has high toughness and wear resistance

3. With overload protection function, once encountered unbreakable or difficult to break the material, the overload protection system of the crusher can effectively protect the machine.

4. The frame should be sprayed with anti-corrosion paint, which can be customized according to the size and height of the transfer vehicle

Sterilization:

Pulsating vacuum: in front of the high temperature sterilization, sterilization of indoor air, set for the high temperature of saturated steam as the sterilization medium, in front of the saturated steam into the sterilizer cavity need to remove the internal air gases, such as interference at the same time make any local confined in the inner chamber areas such as medical waste bags are broken. After this stage, the cold air in the inner chamber is removed to ensure that there is no dead spot in the inner chamber and ensure that the sterilization is qualified.

Drying:

After sterilization, the vacuum pump is started to vacuum the inner chamber, and all the steam in the sterilization room is drawn out. At the same time, the moisture of the waste is greatly reduced under the drying effect of the interlayer.

Discharge:

A wheeled cart is positioned to the discharging port. Discharging door is opened pneumatically on the bottom and then discharging device is opened electrically, Sterilized medical waste is automatically screwed into the cart.

Application:

1. Hospital

2. Healthcare center
 

Parameter MCDS-80 MCDS-250 MCDS-800 Plus
Model (waste density based on 120-200kgs/M3) (waste density based on 120-200kgs/M3) (waste density based on 120-200kgs/M3)
Treatment Capacity each circle 10-15kgs 20-30kg 60-100kgs
Power 27KW 27KW 46KW
Overall dimension(mm) 1650L*1100W*1230H 1650L*1100W*1730H 2200L*1400W*1950H
Details:
Hospital Cssd Lab Polluted Consumables Disposal Medical Waste Harmless Treatment
Hospital Cssd Lab Polluted Consumables Disposal Medical Waste Harmless TreatmentHospital Cssd Lab Polluted Consumables Disposal Medical Waste Harmless Treatment
Company Information:
Hospital Cssd Lab Polluted Consumables Disposal Medical Waste Harmless Treatment
Hospital Cssd Lab Polluted Consumables Disposal Medical Waste Harmless Treatment

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory
Management System Certification
ISO 9001, ISO 13485
Import & Export Mode
Have Own Export License