F15 Medical Equipment Portable Inches LCD Screen Multi-Parameter Patient Monitor

Classification: Physiological Functions of Diagnosis and Monitoring Equipment
Type: Patient Monitor
Certification: CE, FDA
Group: Adult, Pediatric and Neonatal Patient
Display Mode: Standard, Large Font, NIBP Trend, Trend Table, Ful
Printer: Built-in 50mm Thermal Printer (Option)
Customization:
Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
F15
Power Requirements
AC 90-300V, 50/60Hz, 60W
OEM&ODM
Available
Dimension
330mm(W)*260mm(H)*140mm(D)
Certificates
ISO,CE
Transport Package
Export Package
Specification
ISO, CE
Trademark
WANROOEMED
Origin
Jiangsu, China (Mainland)
HS Code
94029000
Production Capacity
1000set/Sets Per Month

Product Description

F15    Medical Equipment Portable Inches LCD Screen Multi-Parameter Patient Monitor
F15 Medical Equipment Portable Inches LCD Screen Multi-Parameter Patient Monitor
Features:
1. 15' color TFT LCD screen supports display max. 11 waveforms
2. Personated voice reminding alarm; Visual On-display and integrated alarm light
3. Display mode: Standard, Large Font, NIBP Trend, Trend Table, Full lead ECG, Oxy CRG.
4. Drug calculation and titration table
5. Real time ST segment analysis, pace maker detection and Arrhythmia analysis,
6. Extended advance function: IBP, IOC, EtCO2, Multi-gas/O2
7. Suitable for monitoring adult, pediatric and neonatal patient.
8. Supporting storage of 720 hours patient data, 1000 NIBP records and 500 alarm event.
9. Internal lead-acid battery
10. Multi-language: Chinese, English, Spanish, Portuguese, Russian, French, German, Czech,
Denish, Dutch, Finland, Italian, Porlish, Turkish

Standard Configuration:
Anti-glare big screen, rechargeable lead-acid battery, 3/5-Lead ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature
Optional Configuration:
1. 2IBP, Nellcor SpO2, Depth of Anesthesia Monitoring Module, EtCO2 (Main-stream/Side-stream/ Micro-stream CO2), Multi-Gas/ O2, Pitch Tone
2. VGA, Thermal printer (50 mm)
3. Roller stand with locking castors and intergrades castors
4. Pediatric / neonatal accessories: reusable NIBP cuff & SpO2 probe; disposable NIBP cuff & SpO2 probe
Central Monitoring System

F15 Medical Equipment Portable Inches LCD Screen Multi-Parameter Patient Monitor
 
Physical Specifications
Dimension and weight Dimension 330mm(W)*260mm(H)*140mm(D)
Weight standard configuration: 4 kg
Operation environment Power requirements AC 90-300V, 50/60HZ, 60W
Power 90VA
Temperature 0-40ºC
Humidity 0-93% non-condensing
Safety Meet the requirements of IEC60601 series
Patient range Adult, neonate and pediatric patients
Performance Specification
Display                        15' color TFT LCD screen, support external VGA(option). rolling and refreshing waveform display
Display mode Standard, large font, NIBP trend, trend table, full lead ECG, Oxy CRG.
Interface Parameter cable interface
AC power input socket
Network interface
External VGA interface for connection of alternate display
Battery 1 internal rechargeable lead-acid battery, 2.0Ah 12V
Alarm indicator Visual on-display and integrated alarm light
Audible alarm and personated voice reminding alarm
Data storage 720 hours monitoring data
10000NIBP records storage
500 alarm event.
Printer Built-in 50mm thermal printer (option),
3 traces, print speed 12.5mm/s & 25mm/s & 50mm/s
print width:50mm
Net working Support connection to central monitoring station through LAN (TCP/IP) or wireless connection
ECG
Leads type 3/5-lead : I, II, III, aVR, aVL, aVF, V
Sweep speed 12.5mm/s, 25mm/s,50mm/s
Gain selection ×0.25,×0.5, ×1, ×2
ECG waveform 3 channels
Operation mode Diagnostic, monitor, surgery
Heart rate range 15 -350bpm
Accuracy 1bpm or ±1% whichever is great
Alarm range Audible and visual alarm, adjustable
ST/ arrhythmia Real time S-T segment detection, pace detection and arrhythmia analysis
Protection Against electrosurgical interference and defibrillation
Respiration (RESP)
Method Thoracic impedance
Operation mode Auto/manual
Measurement range Adult: 0-120BrPM; neonatal /pediatric: 0-150BrPM
Apnea alarm Yes
Alarm Yes, audible and visual alarm ,alarm events recallable
NIBP
Method Automatic oscillometric
Operation mode Manual/Automatic/STAT
Auto measure time Adjustable
Measurement unit mmHg / kPa  selectable
Test interval 1-480 minutes
Measurement range Adult: 0-300 mmHg ;  
Child: 0-240 mmHg ;   
Infant: 0-150 mmHg
Over-pressure protection Double safety protection
Accuracy of blood pressure      measurement The mean error shall be less than±5mmHg
the standard deviation shall be less than 8mmHG
Resolution 1 mmHg
SpO2
Measurement range 0%-100%
Resolution 1%
Accuracy ±2% (70-100%, adult/pediatric, non-motion )
±3% (70-100%, neonate, non-motion )
±3% (70-100%, adult/pediatric/neonate, motion )
0-69% unspecified
Alarm range 1-100%
Pulse rate                      Pulse range: 0-350bpm
Accuracy: ±3bpm(non-motion)
±5bpm(motion )
Temperature (TEMP)
TEMP range 0-50ºC
Resolution 0.1 ºC
Accuracy ±0.1ºC  (excluding the sensor)
Channel Dual-channel. provide T1;T2; T
IBP
Measurement range -50-360mmHg
Channel 2 channels
Pressure transducer Sensitive :5u V/V mmHg
Impedance range :300-3000 Ω
Pressure names ART,PA,CVP,RAP,LAP,ICP,P1,P2
Alarm range -10-300 mmHg
PR from IBP Range & Accuracy: 25-200bpm  ±1bpm or ±1bpm which is greater
201-350bpm ±2%
Resolution : 1bpm
Depth of Anesthesia (BIS)
EEG sensitivity +/- 475μV
Noise < 2uVp-p (1-150 Hz)
CMRR > 100 dB
Input impedance > 50mohm
Sample rate 1024 samples/s, 16 bits
Index and display update 0-100, filter 1-47 Hz, 1 sec. display update
EEG waveform ± 500 µV scaleable, filter 1-30 Hz, 3 sec. window length.                            
ESR 0-100%
EMG 0-100 arbitrary unit Curve and bar
Index trend 5 min and 60 min
Digital output Wireless BT interface (RFCOMM). 10 meters range
Alarms IoC high and low user selectable limits
Artifact rejection Automatic: user can disable.
Sensor impedance range 0 - 14kohm
EtCO2 (Main-stream / Side-stream / Micro-stream CO2)
Measurement range 0-150mmHg
Accuracy ±2mmHg(0-40mmHg)
±5% of reading(41-76mmHg)
±10% of reading (77-99mmHg)
Resolution 1mmHg
Sampling rate 70m1/min 100m1/min
Sampling rate accuracy 0.15 or 15m1/min
Start-up time 30 Sec. the module enters the warming up status after the start up.
1 minute later, it enters the ready-to-measure status.
Respiration rate 3-150 rpm
Respiration rate accuracy ±2BrPM (0-70BrPM)
±5BrPM (>70BrPM)
Response time


 
When measured with a neonatal water trap and a 2.5 m-long neonatal sampling line:
< 3s @ 100 ml/min 
<4 s @ 70 ml/min
When measured with an adult water trap and a 2.5 m-long adult sampling line:
<5.5 s @ 100 ml/min 
<7 s @ 70 ml/min
Delay time


 
When measured with a neonatal water trap and a 2.5m-long neonatal sampling line:
<3 s @ 100 ml/min
<3.5 s @ 70 ml/min
When measured with an adult water trap and a 2.5m-long adult sampling line:
<5 s @ 100 ml/min
<6.5 s @ 70 ml/min
Multi-Gas/O2
Method Infrared absorption
Gas sorts CO2, N2   CO2, N2O, Des, Iso, Enf, Sev, Hal, O2,
(Optional paramagnetic sensor)
Measurement range


 
CO2: 0~30%
N2O : 0~105%
O2,  :0~105%
Enf, Iso, Hal: 0~30%
Sev: 0~30%
Des:0~30%
Data output Fi and ET values
Respiration rate ±1BrPM(2~60BrPM)
61~100BrPM (unspecified)
Other Up to 4 waveforms displayed
Agent mixture detection
MAC value displayed


Company Information:
F15 Medical Equipment Portable Inches LCD Screen Multi-Parameter Patient Monitor
F15 Medical Equipment Portable Inches LCD Screen Multi-Parameter Patient Monitor
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory
Management System Certification
ISO 9001, ISO 13485
Import & Export Mode
Have Own Export License