Hb100 Infant Warmer Care Equipments Hospital Premature Baby Neonatal Medical Incubator

Type: Baby Incubator
Function: Infant Incubator
Theory: Infant Incubator
Certification: CE, FDA
LCD Display: Without LCD Display
Group: Baby
Customization:
Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
HB100
Hood with Dual Slope
4 Hand-Ports
Power Failure Alarm
Yes
Purpose
Infant Care
Instant Parameter Displaying
Set Temp, Air Temp, Heat Power Rate
Temperature Controlled by Microcomputer
Air Temp
Transport Package
Export Carton Package
Specification
CE, ISO
Trademark
WANROOEMED
Origin
China
HS Code
94029000
Production Capacity
1000 Sets/Month

Product Description

Hb100 Infant Warmer Care Equipments Hospital Premature Baby Neonatal Medical Incubator
Hb100 Infant Warmer Care Equipments Hospital Premature Baby Neonatal Medical Incubator

1. Instant Parameter Displaying: Set temp, air temp, heat power rate;
2. Audible & Visual Alarms: Power failure, sensor failure, higher/lower temp, air temperature override, fan failure;
3. Power failure reset memory and self-test function;
4. Hood with dual slope: 4 hand-ports.Blue light Phototherapy Unit with up and below,
  HB103 HB102 HB101 HB100
Mattress to Hood 450mm 450mm 450mm 410mm
Observation side of hood Two incline Two incline Two incline Two incline
Operate port 6 6 6 4
Front access panel 826*310mm 826*310mm 826*310mm 826*280mm
Mattress tray size 630*360mm 630*360mm 630*360mm 630*360mm
Power supply ≤400VA ≤400VA ≤400VA ≤400VA
Temperature controlled by microcomputer Air and skin temp
Air temp
Air and skin temp
Air temp
Air temp Air temp
 
Air temp control range 20ºC-37ºC 20ºC-37ºC 20ºC-37ºC 20ºC-37ºC
37ºC-39ºC 37ºC-39ºC 37ºC-39ºC --------
Skin Temp control range 30ºC-37ºC 30ºC-37ºC ----------- ------------
37ºC-38ºC 37ºC-38ºC ------------ -------
Skin Temp sensor accuracy ≤0.3ºC ≤0.3ºC ------------ -------
Humidity display range 5%-99% ------------- --------- --------------
Temperature fluctuation ≤0.5ºC ≤0.5ºC ≤0.5ºC ≤0.5ºC
Mattress temperature uniformity ≤0.8ºC ≤0.8ºC ≤0.8ºC ≤0.8ºC
Temperature rise time ≤30min ≤30min ≤30min ≤30min
Noise level within hood environment ≤55dB ≤55dB ≤55dB ≤55dB
Alarms        
Power failure alarm yes Yes yes yes
Fan failure alarm yes Yes yes yes
Sensor failure alarm yes Yes yes yes
High air temp alarm +1.5ºC +1.5ºC +1.5ºC +1.5ºC
Low air tem alarm -2.5ºC -2.5ºC -2.5ºC -2.5ºC
High skin temp alarm +1.0ºC +1.0ºC ---- ---
Low skin tem alarm -1.0ºC -1.0ºC -----  
Over air tem alarm ≤38ºC, ≤40ºC ≤38ºC, ≤40ºC ≤38ºC, ≤40ºC ≤38ºC 
Over skin tem alarm ≤38ºC, ≤39ºC ≤38ºC, ≤39ºC ≤38ºC, ≤39ºC --
System failure alarm yes yes yes --
Alarm silence function yes yes yes ---
Operational condition        
Environment temperature +20ºC-+30ºC +20ºC-+30ºC +20ºC-+30ºC +20ºC-+30ºC
Environment relative humidity 5%-99% 5%-99% 5%-99% 5%-99%
Environment air velocity of flow <0.3m/s <0.3m/s <0.3m/s <0.3m/s
Others        
RS232 interface yes yes yes yes
Railing yes yes yes ----
Infant bed tilt adjustment ±10° step less ±10° step less ±10° step less ---------
Max load of mattress tray 10kg 10kg 10kg 10kg
IV Pole Max load 2kg 2kg 2kg 2kg
Details:
Hb100 Infant Warmer Care Equipments Hospital Premature Baby Neonatal Medical Incubator
Hb100 Infant Warmer Care Equipments Hospital Premature Baby Neonatal Medical Incubator
Company information:
Hb100 Infant Warmer Care Equipments Hospital Premature Baby Neonatal Medical Incubator
Hb100 Infant Warmer Care Equipments Hospital Premature Baby Neonatal Medical Incubator
Hb100 Infant Warmer Care Equipments Hospital Premature Baby Neonatal Medical Incubator
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory
Management System Certification
ISO 9001, ISO 13485
Import & Export Mode
Have Own Export License