• Ea-13A Hospital Emergency Ambulance Folding Negative Pressure Biological Isolation Chamber
  • Ea-13A Hospital Emergency Ambulance Folding Negative Pressure Biological Isolation Chamber
  • Ea-13A Hospital Emergency Ambulance Folding Negative Pressure Biological Isolation Chamber
  • Ea-13A Hospital Emergency Ambulance Folding Negative Pressure Biological Isolation Chamber
  • Ea-13A Hospital Emergency Ambulance Folding Negative Pressure Biological Isolation Chamber
  • Ea-13A Hospital Emergency Ambulance Folding Negative Pressure Biological Isolation Chamber

Ea-13A Hospital Emergency Ambulance Folding Negative Pressure Biological Isolation Chamber

Color: Blue
Folded: Folded
Certification: ISO, CE
Material: TPU
Number of Belts: Four
Type: Stretcher
Customization:
Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
EA-13A
HEPA Filter
3PCS, 99.99% Efficiency for 0.3μm Particles
Ventilation
≥ 50L/Min
Chamber Noise
≤65dB(a)
Load Bearing
150kg
Transport Package
Export Carton Package
Specification
1900*680*500mm
Trademark
ROOETECH
Origin
China
HS Code
94029000
Production Capacity
500 Sets/Month

Product Description

EA-13A Hospital Emergency Ambulance Folding Negative Pressure Biological Isolation Chamber
Ea-13A Hospital Emergency Ambulance Folding Negative Pressure Biological Isolation Chamber

Working principle:
Negative pressure isolation chamber stretcher for the transport of infectious patients is to implement safe isolation and transfer device for new, sudden and highly infectious patients during the transfer process to prevent further spread of pathogens, protect the external environment from pollution, and reduce the infection of healthy public probability.
The negative pressure isolation cabin for the transport of infectious patients is that the negative pressure generation system is used to establish and maintain the negative pressure environment in the closed cabin. The polluted air in the cabin cannot overflow without purification, thereby providing effective protection for medical personnel; Fresh air can be purified and replenished to the cabin in real-time, maintaining reasonable fresh air and oxygen concentrations in the cabin, which can provide a relatively comfortable environment for patients.

 

Features:
1. Used for isolation and transportation of severe respiratory infections, preventing pathogen spread and reducing infection rate of medical staff.
2. The cabin is made of high-quality, durable, pollution-free and high-strength transparent TPU material, with waterproof and sealed zippers.
3. Arch supported by the support rod, 2 oxygen inlet, for patients infusion and oxygen delivery; There are 10 operating ports and gloves for patient care and maintenance.
4. The battery can be used continuously for at least 4 hours on a full charge.
5. It can be used together with stretcher to facilitate the movement of patients.
The negative pressure of not less than 15Pa is rapidly established within 6.2min.
7. The noise in cabin is not more than 65dB (A).
8. The filtration efficiency of 0.3μm aerosol particles is not less than 99.99%.
9. Air change in cabin is not less than 50L/min.
10. Sound and light alarm will be made in isolation cabin when the internal negative pressure is insufficient or the electric quantity is too low.
11. When unloaded, the total weight of the cabin shall not be more than 20Kg.
12. Optional stretcher can bear up to 150Kg.
13. It is equipped with 8 long aluminum rods and 4 short aluminum rods to support the cabin, prevent the cabin from shaking and collapsing, and keep the negative pressure stable.
14. The inner plate of the cabin isolation room is equipped with straps for securing the patient and an outer strap for securing the isolation room to a stretcher or bed.
15. The cabin is equipped with three high efficiency filters (canisters) to ensure safety
16. The battery lasts about 10 hours on a full charge.
17. When the internal negative pressure is insufficient or the electric quantity is too low, sound and light alarm should be conducted in the isolation room.
18. The isolation chamber is a fully foldable device that requires minimal storage space and can be used within minutes.

 

Installation:
1.Medical staff takes out the stretcher. Then they should open it, lay it flat and lock it.
2.After that, please place the isolation cabin on a stretcher, lock it with the safety belt that comes with the isolation cabin, adjust the tightness of the safety belt and fix the location of the isolation cabin.
3.First, open the zipper between the bilge and the cabin body of the negative pressure isolation cabin. After the cabin body is opened, please put the patient in, pull the zipper and close the cabin body.
4.Turn on the switch and check the reading on the display. If the negative pressure requirement is not met, please check that all the zippers are closed and the reading is less than 15Pa.
5.The medical staff can carry out simple operations in the cabin with disposable gloves.
6.After arriving at the destination, the medical staff should open the airtight cabin with protective clothing and remove the patient.

 

Notes:
1. Used negative pressure isolation stretchers should be cleaned and disinfected in time.
2. The negative pressure isolation stretcher cannot be exposed to the sun and the wind and rain for a long time. It should be kept in a cool place. Keep the negative pressure isolation stretcher clean inside.
3. Pay attention to timely charging before standby and use. Please calculate the time after power off, don't forget to charge it in time after use, in order to prepare the next use
4. Please operate carefully during disassembly and installation to avoid scraping and breaking of the negative pressure isolation compartment envelope.
5.Please do not unzip the entrance of the infected person when transporting the infected person, so as to avoid leakage of the source of the disease.

Model EA-13A
Unfolded Size (L*W*H) 1900*680*500mm
HEPA Filter 3pcs, 99.99% efficiency for 0.3μm particles
Ventilation ≥ 50L/min
Chamber Noise ≤65dB(A)
Alarm Audio and visual alarm for internal pressure insufficient and low power
Negative Pressure ≥15 Pa in two minutes after power on
Standard Accessory The main chamber, 3pcs disposable HEPA filter, Negative generation system, 5   pairs PE gloves, Battery and charger, 8 long aluminum rods, 4 short aluminum rods,8 knurled bolts
Consumables HEPA filter (3pcs/set), PE gloves
Disinfection Disinfect the chamber with formalin and neutralize with ammonium hydrogen carbonate
Optional Folding stretcher; Stretcher trolley
Load-Bearing Up to 150kg
Power Supply DC12V power adapter. Battery charging for 12 hours and continuously using for 10 hours
Package Size (L*W*H) 870*680*740mm
N.W./G.W. 20kg/38kg

Details:

Ea-13A Hospital Emergency Ambulance Folding Negative Pressure Biological Isolation Chamber
Ea-13A Hospital Emergency Ambulance Folding Negative Pressure Biological Isolation Chamber
Ea-13A Hospital Emergency Ambulance Folding Negative Pressure Biological Isolation Chamber

Ea-13A Hospital Emergency Ambulance Folding Negative Pressure Biological Isolation Chamber
Company Information:
Ea-13A Hospital Emergency Ambulance Folding Negative Pressure Biological Isolation Chamber

Ea-13A Hospital Emergency Ambulance Folding Negative Pressure Biological Isolation Chamber

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory
Management System Certification
ISO 9001, ISO 13485
Import & Export Mode
Have Own Export License